A Two Unit Parallel System with Inspection, Repair and Post Repair
Analyzing System Effectiveness in a Two-Unit Parallel System with Inspection and Repair
Keywords:
two-unit parallel system, inspection, repair, post repair, redundant system model, regenerative point technique, system effectiveness, inspection time, type-I repair time, type-II repair timeAbstract
This paper deals with a two-unit active (Parallel) redundant system model with two types of repair Ist and IInd. Whenever a unit fails it requires inspection to decide whether the failed unit needs type I repair or type II repair. Inspection time, type-I repair time, type-II repair time and post repair time distributions are also negative exponential. Various measures of system effectiveness are obtained by using regenerative point technique.Downloads